You appear to be using incognito/private browsing mode or an ad blocker, which may adversely affect your experience on the site. Please disable any ad blockers and view the site in non-private mode.
{
"ProductData": {
"RelatedLinks": "",
"RegulatoryDisclaimer1": "For use in quality control / manufacturing process only.",
"RegulatoryDisclaimer2": "",
"StainLocalization": [
""
],
"ProductType": "Others",
"DisclaimerGroup2": null,
"ProductNameGlobal": "ISE Sodium Electrode Bio",
"DisclaimerGroup1": "Non-IVD",
"ControlTissue": [
""
],
"BrandName": "ISE Sodium Electrode Bio",
"LicenseDisclaimers": [
],
"Isotypes": "",
"RegulatoryDisclaimer3": "",
"ID": "3.8.10.2.5.4",
"ProductNameAddition": "Test kit for the Cedex Bio Analyzer",
"Species": [
""
],
"Clone": ""
},
"ProductImageDetails": {
"ImagePath": "https://pim-media.roche.com/Images/Article_06437184001_im_en.png",
"ImageType": "Image main"
},
"Product2Taxomony": {
"Product2TaxomonyReferences": [
{
"StructureSystemIdentifier": "OWP_Product_Solutions",
"StructureSystemName": "OWP Product Solutions",
"NodeName": "CustomBiotech",
"NodeID": "520"
},
{
"StructureSystemIdentifier": "OWP_Product_Types",
"StructureSystemName": "OWP Product Types",
"NodeName": "Assays Reagents and Strips",
"NodeID": "20-000-00"
},
{
"StructureSystemIdentifier": "OWP_Organization",
"StructureSystemName": "OWP Organization",
"NodeName": "Roche Diagnostics Solution (RDS)->Customer Areas->Core lab->CustomBiotech and LifeScience",
"NodeID": "01-01-01-07-00"
},
{
"StructureSystemIdentifier": "Product_Grouping",
"StructureSystemName": "Product Grouping",
"NodeName": "CustomBiotech->Cedex Bio Analyzer Products",
"NodeID": "02-0009"
},
{
"StructureSystemIdentifier": "OWP_Family",
"StructureSystemName": "Family",
"NodeName": "Cedex",
"NodeID": "490"
},
{
"StructureSystemIdentifier": "Product_Solutions",
"StructureSystemName": "Product Solutions",
"NodeName": "CustomBiotech",
"NodeID": "520"
}
]
},
"Product2Materials": {
"P2MaterialReferences": [
{
"MaterialNum": "06437184001",
"MaterialDescription": "ISE SODIUM ELECTRODE BIO",
"RegisteredProductName": "ISE Sodium Electrode Bio",
"GTIN": "04015630893317",
"ProductCategoryText": "Consumables",
"OldMaterialNumber": "",
"PackSizePIM360": "1 electrode",
"PackSizeDescPIM360": "",
"MaterialAnnotation": "CustomBiotech product. Please contact your local representative.",
"ReadyForUse": "undefined",
"OrderInformation": "Unit of measure is \"piece\"."
}
]
},
"Product2Products": {
"Product2ProductReference": [
{
"ProductID": "3.8.10.2.5.9",
"BrandName": "ISE Calibrator Indirect Bio",
"ProductNameAddition": "Calibrator reagent for the Cedex Bio Analyzer",
"ReferenceType": "Reagent"
},
{
"ProductID": "3.8.10.1.2.16",
"BrandName": "Control A Level 1 Bio",
"ProductNameAddition": "for Cedex Bio and Cedex Bio HT Analyzers",
"ReferenceType": "Reagent"
},
{
"ProductID": "3.8.10.2.5.7",
"BrandName": "ISE Calibration Kit Bio",
"ProductNameAddition": "Calibrator reagent for the Cedex Bio Analyzer",
"ReferenceType": "Reagent"
},
{
"ProductID": "3.8.10.1.2.18",
"BrandName": "Control A Level 3 Bio",
"ProductNameAddition": "for Cedex Bio and Cedex Bio HT Analyzers",
"ReferenceType": "Reagent"
},
{
"ProductID": "3.8.10.2.5.11",
"BrandName": "ISE Deproteinizer Bio",
"ProductNameAddition": "System reagent for the Cedex Bio Analyzer",
"ReferenceType": "Reagent"
},
{
"ProductID": "3.8.10.2.5.10",
"BrandName": "ISE Etcher Bio",
"ProductNameAddition": "System reagent for the Cedex Bio Analyzer",
"ReferenceType": "Reagent"
},
{
"ProductID": "3.8.10.2.5.8",
"BrandName": "ISE Reference Solution Bio",
"ProductNameAddition": "Calibrator reagent for the Cedex Bio Analyzer",
"ReferenceType": "Reagent"
},
{
"ProductID": "3.8.10.1.2.17",
"BrandName": "Control A Level 2 Bio",
"ProductNameAddition": "for Cedex Bio and Cedex Bio HT Analyzers",
"ReferenceType": "Reagent"
},
{
"ProductID": "3.8.10.1.1.3",
"BrandName": "Activator Bio",
"ProductNameAddition": "System reagent for the Cedex Bio and Cedex Bio HT Analyzers",
"ReferenceType": "Reagent"
},
{
"ProductID": "3.8.10.2.5.1",
"BrandName": "ISE Reference Electrode Bio",
"ProductNameAddition": "Test kit for the Cedex Bio Analyzer",
"ReferenceType": "Consumable"
}
]
},
"ProductSpec": [
{
"ProductSpecVariant": {
"Chapters": [
{
"Language": "en",
"Value": "Unit of measure is \"piece\".",
"Name": "CB - Order Information"
},
{
"Language": "en",
"Value": "Sensor for determination of Sodium.",
"Name": "Positioning"
},
{
"Language": "en",
"Value": "The ISE Sodium Electrode Bio is intended for quantitative determination of sodium in aqueous solutions using the Cedex Bio Instrument. The ISE unit uses flow-through ion-selective electrodes and a reference electrode with an open liquid junction. Each electrode has a membrane that is sensitive to a particular type of ion, in this case sodium ions.",
"Name": "Product Description"
},
{
"Language": "en",
"Value": "The ISE Sodium Electrode Bio is intended for quantitative determination of sodium in aqueous solutions using the Cedex Bio HT Instrument. The ISE unit in the instrument uses ion-selective electrodes - in this case sensitive to sodium ions - and compares the electical potential upon contact to the sample solution to the signal of a reference electrode. The signal difference is used to calculate the sodium concentration refering to the signals of calibrator solutions.",
"Name": "Applications"
},
{
"Language": "en",
"Value": "Sensor is function tested.",
"Name": "Specification"
},
{
"Language": "en",
"Value": "
Electrode
Label
Function / description
Content
1
ISE Sodium Electrode Bio
1 sodium electrode for use with the Cedex Bio Analyzer.