"ProductData": {
"RelatedLinks": "",
"RegulatoryDisclaimer1": "For use in quality control / manufacturing process only.",
"RegulatoryDisclaimer2": "",
"StainLocalization": [
""
],
"ProductType": "Others",
"DisclaimerGroup2": null,
"ProductNameGlobal": "Total Protein Bio HT",
"DisclaimerGroup1": "Non-IVD",
"ControlTissue": [
""
],
"BrandName": "Total Protein Bio HT",
"LicenseDisclaimers": [
],
"Isotypes": "",
"RegulatoryDisclaimer3": "",
"ID": "3.8.10.3.4.14",
"ProductNameAddition": "Test kit for the Cedex Bio HT Analyzer",
"Species": [
""
],
"Clone": ""
},
"ProductImageDetails": {
"ImagePath": "https://pim-media.roche.com/Images/Article_06990169001_im_en.png",
"ImageType": "Image main"
},
"Product2Taxomony": {
"Product2TaxomonyReferences": [
{
"StructureSystemIdentifier": "OWP_Product_Solutions",
"StructureSystemName": "OWP Product Solutions",
"NodeName": "CustomBiotech",
"NodeID": "520"
},
{
"StructureSystemIdentifier": "OWP_Product_Types",
"StructureSystemName": "OWP Product Types",
"NodeName": "Assays Reagents and Strips",
"NodeID": "20-000-00"
},
{
"StructureSystemIdentifier": "OWP_Organization",
"StructureSystemName": "OWP Organization",
"NodeName": "Roche Diagnostics Solution (RDS)->Customer Areas->Core lab->CustomBiotech and LifeScience",
"NodeID": "01-01-01-07-00"
},
{
"StructureSystemIdentifier": "Product_Grouping",
"StructureSystemName": "Product Grouping",
"NodeName": "CustomBiotech->Cedex Bio HT Analyzer Products",
"NodeID": "02-0010"
},
{
"StructureSystemIdentifier": "OWP_Family",
"StructureSystemName": "Family",
"NodeName": "Cedex",
"NodeID": "490"
},
{
"StructureSystemIdentifier": "Product_Solutions",
"StructureSystemName": "Product Solutions",
"NodeName": "CustomBiotech",
"NodeID": "520"
}
]
},
"Product2Materials": {
"P2MaterialReferences": [
{
"MaterialNum": "06990169001",
"MaterialDescription": "Total Protein Bio HT",
"RegisteredProductName": "Total Protein Bio HT",
"GTIN": "07613336133231",
"ProductCategoryText": "Reagents, kits",
"OldMaterialNumber": "",
"PackSizePIM360": "300 tests",
"PackSizeDescPIM360": "",
"MaterialAnnotation": "CustomBiotech product. Please contact your
local representative.",
"ReadyForUse": "true",
"OrderInformation": "Unit of measure is \"piece\"."
}
]
},
"Product2Products": {
"Product2ProductReference": [
{
"ProductID": "3.8.10.1.2.16",
"BrandName": "Control A Level 1 Bio",
"ProductNameAddition": "for Cedex Bio and Cedex Bio HT Analyzers",
"ReferenceType": "Reagent"
},
{
"ProductID": "3.8.10.1.2.18",
"BrandName": "Control A Level 3 Bio",
"ProductNameAddition": "for Cedex Bio and Cedex Bio HT Analyzers",
"ReferenceType": "Reagent"
},
{
"ProductID": "3.8.10.1.2.17",
"BrandName": "Control A Level 2 Bio",
"ProductNameAddition": "for Cedex Bio and Cedex Bio HT Analyzers",
"ReferenceType": "Reagent"
},
{
"ProductID": "3.8.10.1.2.15",
"BrandName": "Calibrator A Bio",
"ProductNameAddition": "for Cedex Bio and Cedex Bio HT Analyzers",
"ReferenceType": "Reagent"
}
]
},
"ProductSpec": [
{
"ProductSpecVariant": {
"Chapters": [
{
"Language": "en",
"Value": "Store the reagent cassette at +2 to +8°C.",
"Name": "Storage Conditions (Product)"
},
{
"Language": "en",
"Value": "Keep at +2 to +15°C for on-board use.
After first use on the instrument, the reagents are stable for up to 4 weeks.
",
"Name": "Storage Conditions (Working Solution)"
},
{
"Language": "en",
"Value": "
Vial | Content | Composition |
---|
TP2B | Reagent cassette, 300 tests | Reagent 1 (R1): Sodium hydroxide, 400 mmol/L, pH 13.4; sodium potassium tartrate, 89 mmol/L; non-reactive surfactant. |
Start Reagent (SR): Sodium hydroxide, 400 mmol/L, pH 13.2; sodium potassium tartrate, 89 mmol/L; potassium iodide, 61 mmol/L, pH 7.3; copper(II) sulfate, 24.3 mmol/L; non-reactive surfactant; preservative. |
",
"Name": "Content"
},
{
"Language": "en",
"Value": "
Test ProtocolTP2B is the standard protocol for total protein determination.If the protein concentration of samples is expected to be lower than 4 g/L, use the protocol TP2LB, which has a higher sensitivity (15-fold higher sample input). If the protein concentration of samples is higher than 120 g/L, use protocol TP2D (same protocol with preset 1:10 sample predilution).Test definition | TP2LB | TP2B | TP2D |
---|
Range | Low range0.3 to 6.0 g/L | High range4 to 120 g/L | High + dilution40 to 1200 g/L |
Predilution | No | No | 1:10 |
Measuring mode | Absorbance | Absorbance | Absorbance |
Abs. calc. mode | Endpoint | Endpoint | Endpoint |
Reaction mode | R1-S-SR | R1-S-SR | R1-S-SR |
Reaction direction | Increase | Increase | Increase |
Wavelength | 552/659 nm | 552/659 nm | 552/659 nm |
Calculation first/last | 33/52 | 33/52 | 33/52 |
Unit | g/L | g/L | g/L |
Pipettingparameters | TP2LB | TP2B | TP2D |
---|
Samplepredilution | No | No | 20 μL+ 180 μL H2O |
R1 | 90 μL | 90 μL | 90 μL |
Sample | 30 μL | 2 μL+ 28 μL H2O | 2 μL+ 28 μL H2O |
SR | 32 μL | 32 μL | 32 μL |
Total volume | 152 μL | 152 μL | 152 μL |
Calibration:Calibrator Calibrator A Bio (CAL A, 07-1100-4)Calibration mode Linear regressionCalibration interval TP2B; TP2D: Each lot, and if recalibration is required due to QC results. TP2BL: After 7 days, and if recalibration is required due to QC results.Quality control:Control A Level 1 Bio (CONA1, 07-1101-2)Control A Level 2 Bio (CONA2, 07-1103-9)Control A Level 3 Bio (CONA3, 07-1104-7)Use the recommended control material. For quality control in the low range of test protocol TP2LB, prepare an appropriate control by diluting \"Control A Level 1 Bio\" 1:10 using water as the diluent. Divide the Total Protein concentration of the original control level 1 by 10 for entering the lot-specific Total Protein value. The corresponding \"1s\" value should be divided by 5, to allow a slightly higher imprecision with the manual dilution step. Other suitable control material can be used in addition.Control intervals and acceptance limits should be adapted to each laboratory's individual requirements.If values do not fall within the defined limits, corrective measures and recalibration are required",
"Name": "Protocols - Help Corner"
},
{
"Language": "en",
"Value": "Kit for determination of the total protein concentration.",
"Name": "Product Description"
},
{
"Language": "en",
"Value": "Unit of measure is \"piece\".",
"Name": "CB - Order Information"
},
{
"Language": "en",
"Value": "- Cedex Bio HT Analyzer*, including accessories and disposables
- Standard laboratory equipment
- Calibrator A Bio*
- Control A Level 1 Bio*
- Control A Level 2 Bio*
- Control A Level 3 Bio*
",
"Name": "Additional Equipment and Reagent Required"
},
{
"Language": "en",
"Value": "Total protein concentration can be determined in following range:- TP2LB: 0.3 to 6.0 g/L
- TP2B: 4 to 120 g/L
- TP2D: 40 g/L up to maximal solubility
TraceabilityThis method has been standardized against a standard reference material (SRM 927).PrecisionRepresentative performance data on Cedex Bio HT Analyzers are shown. Results obtained in individual laboratories may differ.Precision was determined in samples of three concentration levels. Coefficients of variation (CV) were calculated for in-run precision (n=21) and inter-run precision (on 21 days). | Level 1 | Level 2 | Level 3 |
---|
Mean | 52.6 g/L | 65.4 g/L | 92.0 g/L |
CV in-run | 0.5% | 0.5% | 1.0% |
CV inter-run | 1.0% | 1.5% | 2.2% |
",
"Name": "Background Information - Help Corner"
},
{
"Language": "en",
"Value": "In the process control of cell cultures and microbial fermentation, as well as in a down-stream protein isolation process, the generic determination of the total protein concentration can be used for control of culture media, for monitoring of the increase of secreted protein products in a culture, and to check the content of a purified protein in an isolation process. The total protein concentration can be determined on a Cedex Bio or Cedex Bio HT Analyzer with high reliability and convenience.",
"Name": "Applications"
},
{
"Language": "en",
"Value": "Method: Colorimetric biuret reaction with copper ions.
Recovery: ±10%",
"Name": "Specification"
},
{
"Language": "en",
"Value": "- Handle all samples as if potentially infectious, using safe laboratory procedures. As the sensitivity and titer of potential pathogens in the sample material can vary, the operator must optimize pathogen inactivation and follow the appropriate measures according to local safety regulations.
- Do not eat, drink, or smoke in the laboratory work area.
- Do not pipette by mouth.
- Wear protective disposable gloves, laboratory coats, and eye pro\u00adtection, when handling samples and kit reagents.
- Wash hands thoroughly after handling samples and reagents.
- Discard unused reagents and waste in accordance with country, federal, state, and local regulations.
- Safety Data Sheets (SDS) are available online at dialog.roche.com, or upon request from the local Roche office.
",
"Name": "Safety Information"
}
]
}
}
]
}