{ "ProductData": { "ID": "3.8.10.3.4.22", "ProductType": "Others", "BrandName": "Formate Bio HT", "ProductNameAddition": "Test kit for the Cedex Bio HT Analyzer", "RegulatoryDisclaimer1": "For use in quality control/manufacturing process only.", "DisclaimerGroup1": "", "RegulatoryDisclaimer2": null, "DisclaimerGroup2": null, "RegulatoryDisclaimer3": null, "SampleType": [ ], "LicenseDisclaimers": [ ], "RelatedLinks": "", "Clone": "", "ControlTissue": [ "" ], "ISOtypes": "", "Species": [ "" ], "StainLocalization": [ "" ], "ProductNameGlobal": "Formate Bio HT" }, "ProductImageDetails": { "ImagePath": "https://pim-media.roche.com/Images/Article_07705603001_im_en.png", "ImageType": "Image main" }, "Product2Taxonomy": { "Product2TaxonomyReferences": [ { "StructureSystemIdentifier": "OWP_Product_Types", "StructureSystemName": "Product Types", "StructureNodeStatus": "valid", "NodeName": "Assays Reagents and Strips", "NodeID": "20-000-00" }, { "StructureSystemIdentifier": "OWP_Organization", "StructureSystemName": "Organization", "StructureNodeStatus": "valid", "NodeName": "CustomBiotech and LifeScience", "NodeID": "01-01-01-07-00" }, { "StructureSystemIdentifier": "Product_Grouping", "StructureSystemName": "Product Grouping", "StructureNodeStatus": "valid", "NodeName": "Cedex Bio HT Analyzer Products", "NodeID": "02-0010" }, { "StructureSystemIdentifier": "OWP_Family", "StructureSystemName": "Product Families", "StructureNodeStatus": "valid", "NodeName": "Cedex", "NodeID": "490" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "StructureNodeStatus": "valid", "NodeName": "CustomBiotech", "NodeID": "520" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "180-00" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "OWP_Techniques", "StructureSystemName": "Techniques", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "999-00" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Disease_Areas", "StructureSystemName": "Disease Areas", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Pathogens", "StructureSystemName": "Pathogens", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Product_Grouping", "StructureSystemName": "Product Grouping", "StructureNodeStatus": "valid", "NodeName": "Cell and Gene Therapy", "NodeID": "02-0133" } ] }, "Product2Materials": { "P2MaterialReferences": [ { "MaterialNum": "07705603001", "MaterialDescription": "Formate Bio HT", "RegisteredProductName": "Formate Bio HT", "GTIN": "", "ProductCategoryText": "Reagents, kits", "OldMaterialNumber": "", "PackSizePIM360": "200 tests", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "CustomBiotech product. Please contact your local representative.", "ReadyForUse": "true", "OrderInformation": "Unit of measure is \"piece\"." } ] }, "Product2Products": { "Product2ProductReference": [ { "ProductID": "INS_3590", "BrandName": "Cedex Bio HT Analyzer", "ProductNameAddition": "Bioprocess analyzer", "ReferenceType": "Instrument", "Classification": [ { "IdentifierofStructureSystem": "1", "NameofStructureSystem": "GPCH", "StructureNodeID": "8480", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "" }, { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "10-000-00", "StructureGroupPath": "Analyzer Instruments and Systems", "StructureGroupName": "Analyzer Instruments and Systems", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Organization", "NameofStructureSystem": "Organization", "StructureNodeID": "01-01-01-07-00", "StructureGroupPath": "Roche Diagnostics Solution (RDS)->Customer Areas->Core lab->CustomBiotech and LifeScience", "StructureGroupName": "CustomBiotech and LifeScience", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "490", "StructureGroupPath": "Cedex", "StructureGroupName": "Cedex", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "520", "StructureGroupPath": "CustomBiotech", "StructureGroupName": "CustomBiotech", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "180-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "999-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0008", "StructureGroupPath": "CustomBiotech->Biologics", "StructureGroupName": "Biologics", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0133", "StructureGroupPath": "CustomBiotech->Cell and Gene Therapy", "StructureGroupName": "Cell and Gene Therapy", "StructureNodeStatus": "valid" } ] }, { "ProductID": "3.8.10.1.2.30", "BrandName": "Control D Level 2 Bio", "ProductNameAddition": "for Cedex Bio and Cedex Bio HT Analyzers", "ReferenceType": "Control", "Classification": [ { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "90-000-00", "StructureGroupPath": "Controls", "StructureGroupName": "Controls", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Organization", "NameofStructureSystem": "Organization", "StructureNodeID": "01-01-01-07-00", "StructureGroupPath": "Roche Diagnostics Solution (RDS)->Customer Areas->Core lab->CustomBiotech and LifeScience", "StructureGroupName": "CustomBiotech and LifeScience", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0009", "StructureGroupPath": "CustomBiotech->Cedex Bio Analyzer Products", "StructureGroupName": "Cedex Bio Analyzer Products", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0010", "StructureGroupPath": "CustomBiotech->Cedex Bio HT Analyzer Products", "StructureGroupName": "Cedex Bio HT Analyzer Products", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "490", "StructureGroupPath": "Cedex", "StructureGroupName": "Cedex", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "520", "StructureGroupPath": "CustomBiotech", "StructureGroupName": "CustomBiotech", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "180-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "999-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" } ] }, { "ProductID": "3.8.10.1.2.31", "BrandName": "Control D Level 3 Bio", "ProductNameAddition": "for Cedex Bio and Cedex Bio HT Analyzers", "ReferenceType": "Control", "Classification": [ { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "90-000-00", "StructureGroupPath": "Controls", "StructureGroupName": "Controls", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Organization", "NameofStructureSystem": "Organization", "StructureNodeID": "01-01-01-07-00", "StructureGroupPath": "Roche Diagnostics Solution (RDS)->Customer Areas->Core lab->CustomBiotech and LifeScience", "StructureGroupName": "CustomBiotech and LifeScience", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0009", "StructureGroupPath": "CustomBiotech->Cedex Bio Analyzer Products", "StructureGroupName": "Cedex Bio Analyzer Products", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0010", "StructureGroupPath": "CustomBiotech->Cedex Bio HT Analyzer Products", "StructureGroupName": "Cedex Bio HT Analyzer Products", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "490", "StructureGroupPath": "Cedex", "StructureGroupName": "Cedex", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "520", "StructureGroupPath": "CustomBiotech", "StructureGroupName": "CustomBiotech", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "180-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "999-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" } ] }, { "ProductID": "3.8.10.1.2.28", "BrandName": "Calibrator D Bio", "ProductNameAddition": "for Cedex Bio and Cedex Bio HT Analyzers", "ReferenceType": "Calibrator", "Classification": [ { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "80-000-00", "StructureGroupPath": "Calibrators", "StructureGroupName": "Calibrators", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Organization", "NameofStructureSystem": "Organization", "StructureNodeID": "01-01-01-07-00", "StructureGroupPath": "Roche Diagnostics Solution (RDS)->Customer Areas->Core lab->CustomBiotech and LifeScience", "StructureGroupName": "CustomBiotech and LifeScience", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0009", "StructureGroupPath": "CustomBiotech->Cedex Bio Analyzer Products", "StructureGroupName": "Cedex Bio Analyzer Products", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0010", "StructureGroupPath": "CustomBiotech->Cedex Bio HT Analyzer Products", "StructureGroupName": "Cedex Bio HT Analyzer Products", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "490", "StructureGroupPath": "Cedex", "StructureGroupName": "Cedex", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "520", "StructureGroupPath": "CustomBiotech", "StructureGroupName": "CustomBiotech", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "180-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "999-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" } ] }, { "ProductID": "3.8.10.1.2.29", "BrandName": "Control D Level 1 Bio", "ProductNameAddition": "for Cedex Bio and Cedex Bio HT Analyzers", "ReferenceType": "Control", "Classification": [ { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "90-000-00", "StructureGroupPath": "Controls", "StructureGroupName": "Controls", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Organization", "NameofStructureSystem": "Organization", "StructureNodeID": "01-01-01-07-00", "StructureGroupPath": "Roche Diagnostics Solution (RDS)->Customer Areas->Core lab->CustomBiotech and LifeScience", "StructureGroupName": "CustomBiotech and LifeScience", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0009", "StructureGroupPath": "CustomBiotech->Cedex Bio Analyzer Products", "StructureGroupName": "Cedex Bio Analyzer Products", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0010", "StructureGroupPath": "CustomBiotech->Cedex Bio HT Analyzer Products", "StructureGroupName": "Cedex Bio HT Analyzer Products", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "490", "StructureGroupPath": "Cedex", "StructureGroupName": "Cedex", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "520", "StructureGroupPath": "CustomBiotech", "StructureGroupName": "CustomBiotech", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "180-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "999-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" } ] } ] }, "ProductSpec": [ { "ProductSpecVariant": { "Chapters": [ { "Language": "en", "Value": "Store the reagent cassette at +2 to +8°C.", "Country": "XG", "Code": "Storage Conditions (Product)", "Name": "Storage Conditions (Product)" }, { "Language": "en", "Value": "
Analyzer and accessories
  • Cedex Bio HT Analyzer*, including accessories and disposables
  • Standard laboratory equipment
Calibrators and Controls
  • Calibrator D Bio*
  • Control D Level 1 Bio*
  • Control D Level 2 Bio*
  • Control D Level 3 Bio*
", "Country": "XG", "Code": "Additional Equipment and Reagent Required", "Name": "Additional Equipment and Reagent Required" }, { "Language": "en", "Value": "
Test protocol
Cedex Bio HT test definition
Test definitionFORB
(176)
FORD
(181)
Measuring range
     mmol/L
     mg/L
Standard
0.2 – 20
9.0 – 900
High
2.0 – 200(1)
90 – 9,000(1)
Control levelD 1, 2, 3D 2, 3
Sample predilutionNo1:10
Measuring modeAbsorbanceAbsorbance
Abs. calc. modeEndpointEndpoint
Reaction modeR1-R2-SR1-R2-S
Reaction directionIncreaseIncrease
Wavelength A/B340/409 nm340/409 nm
Calc. first/last18/7018/70
Unitmmol/L, mg/Lmmol/L, mg/L
  1. Up to 2 mol/L (90 g/L) with automatic predilution.
Pipetting parameters
Pipetting parametersFORB
(176)
FORD
(181)
Water Diluent (Sample Predilution)(1)No20 μL sample + 180 μL water
R1100 μL + 5 μL water100 μL + 5 μL water
R270 μL + 5 μL water70 μL + 5 μL water
Sample (S)4.5 μL + 18 μL water4.5 μL + 18 μL water
Total Volume202.5 μL202.5 μL
  1. Sample predilution is performed in a prior step, after which the reaction mix is prepared in the same way as the unmodified sample.
Calibration
Calibration
CalibratorCalibrator D Bio (CAL D, 07-1141-1)
Calibration modeLinear regression
Calibration interval140 days, and if recalibration is required due to QC results.
Quality control
Protocol FORB
  • Control D Level 1 Bio (COND1, 07-1143-8)
  • Control D Level 2 Bio (COND2, 07-1144-6)
  • Control D Level 3 Bio (COND3, 07-1145-4)
Protocol FORD
  • Control D Level 2 Bio (COND2, 07-1144-6)
  • Control D Level 3 Bio (COND3, 07-1145-4)

Use the recommended control material. Other suitable control material can also be used.
Control intervals and acceptance limits should be adapted to each lab\u00adoratory's individual requirements. If values do not fall within the defined limits, corrective measures and recalibration are required.
Conversion factors
Conversion factors for formate concentration:
  • 1 mmol/L = 45.02 mg/L
  • 1 g/L = 22.21 mmol/L
Traceability
This method has been standardized against net weight.
Precision
Representative performance data on Cedex Bio HT Analyzers are shown. Results obtained in individual laboratories may differ. Precision was determined in samples of three concentration levels. Coefficients of variation (CV) were calculated for in-run precision (n=21) and inter-run precision (on 10 days).
 Level 1Level 2Level 3
Mean1.0 mmol/L (45 mg/L)8.0 mmol/L (360 mg/L)15.0 mmol/L (675 mg/L)
CV in-run [%]0.80.30.4
CV inter-run [%]1.91.92.1
", "Country": "XG", "Code": "Protocols", "Name": "Protocols" }, { "Language": "en", "Value": "Unit of measure is \"piece\".", "Country": "XG", "Code": "CB - Order Information", "Name": "CB - Order Information" }, { "Language": "en", "Value": "
VialContentComposition
FORBReagent cassette,
200 tests
Reagent 1 (R1): TRIS, 100 mmol/L; sodium chloride, 154 mmol/L; formate dehydrogenase (FDH), approximately 20 U/mL; stabilizer; preservative; pH 7.5.
Reagent 2 (R2): Nicotinamide adenine dinucleotide, 60 mmol/L; preservative; pH 4.6.
", "Country": "XG", "Code": "Content", "Name": "Content" }, { "Language": "en", "Value": "Formate is a relevant metabolyte in microbial fermentation. In a controlled fermentation process, formate should be used by the microbes as source of carbon and energy and should not be accumulated in the medium. For monitoring in a culture process, formate can be determined on a Cedex Bio or Cedex Bio HT Analyzer with high reliability and convenience.", "Country": "XG", "Code": "Applications", "Name": "Applications" }, { "Language": "en", "Value": "Method: Enzymatic photometric assay using formate dehydrogenase.
Recovery: ±15%", "Country": "XG", "Code": "Specification", "Name": "Specification" } ] } } ] }