{ "ProductData": { "ID": "3.8.10.2.4.22", "ProductType": "Others", "BrandName": "Formate Bio", "ProductNameAddition": "Test kit for the Cedex Bio Analyzer", "RegulatoryDisclaimer1": "For use in quality control/manufacturing process only.", "DisclaimerGroup1": "", "RegulatoryDisclaimer2": null, "DisclaimerGroup2": null, "RegulatoryDisclaimer3": null, "SampleType": [ ], "LicenseDisclaimers": [ ], "RelatedLinks": "", "Clone": "", "ControlTissue": [ "" ], "ISOtypes": "", "Species": [ "" ], "StainLocalization": [ "" ], "ProductNameGlobal": "Formate Bio" }, "ProductImageDetails": { "ImagePath": "https://pim-media.roche.com/Images/Article_07705590001_im_en.png", "ImageType": "Image main" }, "Product2Taxonomy": { "Product2TaxonomyReferences": [ { "StructureSystemIdentifier": "OWP_Product_Types", "StructureSystemName": "Product Types", "NodeID": "20-000-00", "StructureNodeStatus": "valid", "NodeName": "Assays Reagents and Strips" }, { "StructureSystemIdentifier": "OWP_Organization", "StructureSystemName": "Organization", "NodeID": "01-01-01-07-00", "StructureNodeStatus": "valid", "NodeName": "CustomBiotech and LifeScience" }, { "StructureSystemIdentifier": "Product_Grouping", "StructureSystemName": "Product Grouping", "NodeID": "02-0009", "StructureNodeStatus": "valid", "NodeName": "Cedex Bio Analyzer Products" }, { "StructureSystemIdentifier": "OWP_Family", "StructureSystemName": "Product Families", "NodeID": "490", "StructureNodeStatus": "valid", "NodeName": "Cedex" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "NodeID": "520", "StructureNodeStatus": "valid", "NodeName": "CustomBiotech" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "NodeID": "180-00", "StructureNodeStatus": "invalid", "NodeName": "" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "NodeID": "99-00-00", "StructureNodeStatus": "invalid", "NodeName": "" }, { "StructureSystemIdentifier": "OWP_Techniques", "StructureSystemName": "Techniques", "NodeID": "999-00", "StructureNodeStatus": "invalid", "NodeName": "" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "NodeID": "99-00-00", "StructureNodeStatus": "invalid", "NodeName": "" }, { "StructureSystemIdentifier": "Disease_Areas", "StructureSystemName": "Disease Areas", "NodeID": "99-00-00", "StructureNodeStatus": "invalid", "NodeName": "" }, { "StructureSystemIdentifier": "Pathogens", "StructureSystemName": "Pathogens", "NodeID": "99-00-00", "StructureNodeStatus": "invalid", "NodeName": "" }, { "StructureSystemIdentifier": "Product_Grouping", "StructureSystemName": "Product Grouping", "NodeID": "02-0133", "StructureNodeStatus": "valid", "NodeName": "Cell and Gene Therapy" } ] }, "Product2Materials": { "P2MaterialReferences": [ { "MaterialNum": "07705590001", "MaterialDescription": "Formate Bio", "RegisteredProductName": "Formate Bio", "GTIN": "", "ProductCategoryText": "Reagents, kits", "OldMaterialNumber": "", "PackSizePIM360": "4 x 50 tests", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "CustomBiotech product. Please contact your local representative.", "ReadyForUse": "true", "OrderInformation": "Unit of measure is \"piece\"." } ] }, "Product2Products": { "Product2ProductReference": [ { "ProductID": "INS_2895", "BrandName": "Cedex Bio Analyzer", "ProductNameAddition": "Bioprocess analyzer", "ReferenceType": "Instrument", "Classification": [ { "IdentifierofStructureSystem": "1", "NameofStructureSystem": "GPCH", "StructureNodeID": "7083", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "" }, { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "10-000-00", "StructureGroupPath": "Analyzer Instruments and Systems", "StructureGroupName": "Analyzer Instruments and Systems", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Organization", "NameofStructureSystem": "Organization", "StructureNodeID": "01-01-01-07-00", "StructureGroupPath": "Roche Diagnostics Solution (RDS)->Customer Areas->Core lab->CustomBiotech and LifeScience", "StructureGroupName": "CustomBiotech and LifeScience", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "490", "StructureGroupPath": "Cedex", "StructureGroupName": "Cedex", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "520", "StructureGroupPath": "CustomBiotech", "StructureGroupName": "CustomBiotech", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "180-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "999-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0008", "StructureGroupPath": "CustomBiotech->Biologics", "StructureGroupName": "Biologics", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0133", "StructureGroupPath": "CustomBiotech->Cell and Gene Therapy", "StructureGroupName": "Cell and Gene Therapy", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0090", "StructureGroupPath": "CustomBiotech->Vaccine Testing", "StructureGroupName": "Vaccine Testing", "StructureNodeStatus": "valid" } ] }, { "ProductID": "3.8.10.1.2.29", "BrandName": "Control D Level 1 Bio", "ProductNameAddition": "for Cedex Bio and Cedex Bio HT Analyzers", "ReferenceType": "Control", "Classification": [ { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "90-000-00", "StructureGroupPath": "Controls", "StructureGroupName": "Controls", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Organization", "NameofStructureSystem": "Organization", "StructureNodeID": "01-01-01-07-00", "StructureGroupPath": "Roche Diagnostics Solution (RDS)->Customer Areas->Core lab->CustomBiotech and LifeScience", "StructureGroupName": "CustomBiotech and LifeScience", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0009", "StructureGroupPath": "CustomBiotech->Cedex Bio Analyzer Products", "StructureGroupName": "Cedex Bio Analyzer Products", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0010", "StructureGroupPath": "CustomBiotech->Cedex Bio HT Analyzer Products", "StructureGroupName": "Cedex Bio HT Analyzer Products", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "490", "StructureGroupPath": "Cedex", "StructureGroupName": "Cedex", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "520", "StructureGroupPath": "CustomBiotech", "StructureGroupName": "CustomBiotech", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "180-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "999-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" } ] }, { "ProductID": "3.8.10.1.2.28", "BrandName": "Calibrator D Bio", "ProductNameAddition": "for Cedex Bio and Cedex Bio HT Analyzers", "ReferenceType": "Calibrator", "Classification": [ { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "80-000-00", "StructureGroupPath": "Calibrators", "StructureGroupName": "Calibrators", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Organization", "NameofStructureSystem": "Organization", "StructureNodeID": "01-01-01-07-00", "StructureGroupPath": "Roche Diagnostics Solution (RDS)->Customer Areas->Core lab->CustomBiotech and LifeScience", "StructureGroupName": "CustomBiotech and LifeScience", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0009", "StructureGroupPath": "CustomBiotech->Cedex Bio Analyzer Products", "StructureGroupName": "Cedex Bio Analyzer Products", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0010", "StructureGroupPath": "CustomBiotech->Cedex Bio HT Analyzer Products", "StructureGroupName": "Cedex Bio HT Analyzer Products", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "490", "StructureGroupPath": "Cedex", "StructureGroupName": "Cedex", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "520", "StructureGroupPath": "CustomBiotech", "StructureGroupName": "CustomBiotech", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "180-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "999-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" } ] }, { "ProductID": "3.8.10.1.2.31", "BrandName": "Control D Level 3 Bio", "ProductNameAddition": "for Cedex Bio and Cedex Bio HT Analyzers", "ReferenceType": "Control", "Classification": [ { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "90-000-00", "StructureGroupPath": "Controls", "StructureGroupName": "Controls", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Organization", "NameofStructureSystem": "Organization", "StructureNodeID": "01-01-01-07-00", "StructureGroupPath": "Roche Diagnostics Solution (RDS)->Customer Areas->Core lab->CustomBiotech and LifeScience", "StructureGroupName": "CustomBiotech and LifeScience", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0009", "StructureGroupPath": "CustomBiotech->Cedex Bio Analyzer Products", "StructureGroupName": "Cedex Bio Analyzer Products", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0010", "StructureGroupPath": "CustomBiotech->Cedex Bio HT Analyzer Products", "StructureGroupName": "Cedex Bio HT Analyzer Products", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "490", "StructureGroupPath": "Cedex", "StructureGroupName": "Cedex", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "520", "StructureGroupPath": "CustomBiotech", "StructureGroupName": "CustomBiotech", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "180-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "999-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" } ] }, { "ProductID": "3.8.10.1.2.30", "BrandName": "Control D Level 2 Bio", "ProductNameAddition": "for Cedex Bio and Cedex Bio HT Analyzers", "ReferenceType": "Control", "Classification": [ { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "90-000-00", "StructureGroupPath": "Controls", "StructureGroupName": "Controls", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Organization", "NameofStructureSystem": "Organization", "StructureNodeID": "01-01-01-07-00", "StructureGroupPath": "Roche Diagnostics Solution (RDS)->Customer Areas->Core lab->CustomBiotech and LifeScience", "StructureGroupName": "CustomBiotech and LifeScience", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0009", "StructureGroupPath": "CustomBiotech->Cedex Bio Analyzer Products", "StructureGroupName": "Cedex Bio Analyzer Products", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "02-0010", "StructureGroupPath": "CustomBiotech->Cedex Bio HT Analyzer Products", "StructureGroupName": "Cedex Bio HT Analyzer Products", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "490", "StructureGroupPath": "Cedex", "StructureGroupName": "Cedex", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "520", "StructureGroupPath": "CustomBiotech", "StructureGroupName": "CustomBiotech", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "180-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "999-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" } ] } ] }, "ProductSpec": [ { "ProductSpecVariant": { "Chapters": [ { "Name": "Storage Conditions (Product)", "Value": "Store the reagent at +2 to +8°C.", "Language": "en", "Country": "XG", "Code": "Storage Conditions (Product)" }, { "Name": "Content", "Value": "
VialCapContentComposition
1 FORB R1white4 vials,
50 tests each
Reagent 1 (R1): TRIS, 100 mmol/L; sodium chloride, 154 mmol/L; formate dehydrogenase (FDH), approximately 20 U/mL; stabilizer; preservative; pH 7.5.
2 FORB R2black4 vials,
50 tests each
Reagent 2 (R2): Nicotinamide adenine dinucleotide, 60 mmol/L; preservative; pH 4.6.
", "Language": "en", "Country": "XG", "Code": "Content" }, { "Name": "Additional Equipment and Reagent Required", "Value": "
Analyzer and accessories
  • Cedex Bio Analyzer*, including accessories and disposables
  • Standard laboratory equipment
Calibrators and Controls
  • Calibrator D Bio*
  • Control D Level 1 Bio*
  • Control D Level 2 Bio*
  • Control D Level 3 Bio*
", "Language": "en", "Country": "XG", "Code": "Additional Equipment and Reagent Required" }, { "Name": "CB - Order Information", "Value": "Unit of measure is \"piece\".", "Language": "en", "Country": "XG", "Code": "CB - Order Information" }, { "Name": "Applications", "Value": "Formate is a relevant metabolyte in microbial fermentation. In a controlled fermentation process, formate should be used by the microbes as source of carbon and energy and should not be accumulated in the medium. For monitoring in a culture process, formate can be determined on a Cedex Bio or Cedex Bio HT Analyzer with high reliability and convenience.", "Language": "en", "Country": "XG", "Code": "Applications" }, { "Name": "Specification", "Value": "Method: Enzymatic photometric assay using formate dehydrogenase.
Recovery: ±15%", "Language": "en", "Country": "XG", "Code": "Specification" } ] } } ] }